Quick Answer
Calculate SLA/DLP Photopolymer Cure Depth vs. Exposure Dose & Oxygen Inhibition Zone Sizing
Calculator
Result Interpretation
SLA/DLP Photopolymer Cure Depth vs. Exposure Dose & Oxygen Inhibition Zone Sizing Calculator computes Cure Depth in m using the defined engineering formula and the input values provided.
Worked Example
Verified calculation
Given:
- Penetration Depth = 0.00012
- Critical Exposure Dose = 8.5
- Exposure Dose = 1200
- Oxygen Inhibition Zone Thickness = 2.5E-6
Expected Result:
- Cure Depth = 0.00058900128067358
Engineering Interpretation:
Under the given input conditions, the calculated result is: Cure Depth = 0.00058900128067358 m.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
cure depth = (penetration depth * log(exposure dose / critical exposure dose)) - (2.0 * oxygen inhibition zone thickness)Formula family: formula_additive_sladlp_photopolymer_cure_depth_vs_exposure_dose_oxygen_inhibition_zone_sizing_tool
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| exposure_dose | Exposure Dose | INPUT | Exposure Dose |
| Ec | Critical Exposure Dose | INPUT | Critical Exposure Dose |
| Dp | Penetration Depth | INPUT | Penetration Depth |
| oxygen_inhibition_zone_thickness | Oxygen Inhibition Zone Thickness | INPUT | Oxygen Inhibition Zone Thickness |
| cure_depth | Cure Depth | OUTPUT | Cure Depth |
Calculation Steps
- Enter the exposure dose in J/m^2.
- Enter the critical exposure dose in J/m^2.
- Enter the penetration depth in m.
- Enter the oxygen inhibition zone thickness in m.
- Step 1: Compute cure depth.
- Read the cure depth (m) from the results.
Engineering Summary
Calculate SLA/DLP Photopolymer Cure Depth vs. Exposure Dose & Oxygen Inhibition Zone Sizing
Frequently Asked Questions
What does this calculator calculate?
The SLA/DLP Photopolymer Cure Depth vs. Exposure Dose & Oxygen Inhibition Zone Sizing Calculator estimates Cure Depth based on the input parameters you provide
Why is exposure dose important in this calculation?
exposure dose is directly proportional to cure depth. When you enter exposure dose in J/m^2, the calculator uses it in the engineering formula to compute the output
How should I interpret the result cure depth?
The calculator outputs cure depth in m. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Exposure Dose (J/m^2), Critical Exposure Dose (J/m^2), Penetration Depth (m), Oxygen Inhibition Zone Thickness (m). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
Additive Lattice Structural Efficiency Index Calculator
FDM Build Plate Adhesion Safety Margin Calculator
FDM Nozzle Volumetric Flow Rate from Layer Height and Melt Viscosity Calculator
Laser Powder Directed Energy Deposition Thermal Gradient Calculator
Powder Bed Fusion Build Orientation-Driven Residual Stress Anisotropy Index Calculator
Browse More Tools
Explore the full index of engineering calculators on this vertical site.